BMS/DCIM Operator
Job Description
REQUIREMENTS
- 2-3 year BMS/DCIM Operator Experience in Data Center Maintenance/Operations.
- 5+ year Total Experience in BMS/DCIM.
Skills required:
- Working knowledge of Electrical & ELV systems including secondary distribution, HVAC System interior systems
- Ability to read CAD Drawings, single-line diagrams, and rough shop drawings
- Possess strong knowledge in multiple skilled trades (electrical, HVAC, plumbing, etc)
- Requires ability to analyze the operation of various infrastructure systems, determine the cause of problems/malfunctions, and take corrective actions as required
- Trained and experienced in BMS/DCIM operation.
- Vigilant with attention for detail.
- Excellent computer operation skills.
- Ability to deal with emergency situations in a calm manner. Integrity, commitment and courteous.
RESPONSIBILITIES
- Operates and maintains Building Management System (BMS) for proper function and monitors the DCIM against approved benchmarks to include; HVAC, Lighting, Fire Suppression, Generator, Plumbing, and Electrical
- Carry out routine checks for correct operation of all control equipment as directed by Facility Engineer
- Monitor the operation of the HVAC control systems using the BMS/DCIM to monitor performance.
- Adjust variables and provide adjustment as required to ensure systems are operating correctly within parameters
- Monitor and record values of HVAC systems to build up a database of records to provide data for energy efficiency improvement.
- Communicate all maintenance and repair actions in writing for information to management as required.
- Should follow the Protocols if any unexpected technical difficulties and other problems that may arise at any time.
- Monitors and verifies operation of all BMS/DCIM field devices.
- Adjusts BMS settings and parameters to meet changing conditions, i.e., Load, Environmental, Customer needs, etc.
- Records maintenance data and generates reports as needed.
- Maintains job card documentation for all Alarms or changes to systems and/or equipment.
- Monitors of fire detection alarm system, such as smoke detector, heat detector, sprinkler, and emergency exit, in coordination with Safety Function.
- Monitors of Water tank supply level alarm, air handling unit, fresh air handling unit.
- Monitors and controls the Fire pump system, motors, sewage pump, electrical system, water system in the Data Center building.
- Performs miscellaneous tasks as assigned by his Facility Engineer
- Daily checking healthiness of all facilities equipment’s and keeping daily logs and records of all maintenance functions.
- Create the Job cards in CAFM (FSI) Mobile App as per Site requirements and close the Job cards which Engineer assigns.
- Responding promptly and efficiently to emergencies calls.
- Review and understand equipment and methods of operation, Electrical systems, ELV system, fire/life safety, and other systems.
- Comply with all safety procedures and requirements
- Support any afterhours building needs and activities as required
- Attend training sessions and seminars.